ThermRite Ltd
160m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit
160m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit
Couldn't load pickup availability
SKU:SP16-160
<p>The <strong>160m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres</strong> is a complete water-based underfloor heating package for a whole-ground-floor heating project. It uses <a href="https://thermriteshop.co.uk/products/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe">SpiderFix16 self-adhesive pipe-fixing panels</a> with a <strong>20mm panel profile</strong> to hold <strong>16mm UFH pipe</strong> in a designed <strong>200mm-centre layout</strong>. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.</p>
<p>An eight-port system for extensive installations needing coordinated circuit layout and commissioning. This 160m² SpiderFix16 kit includes <strong>223 self-adhesive panels, 800m of 16mm pipe, 16 compatible connector cores, a 8-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control</strong>.</p>
<h2>Key benefits of the 160m² SpiderFix16 UFH kit</h2>
<ul>
<li><strong>20mm self-adhesive panels:</strong> low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.</li>
<li><strong>200mm design centres:</strong> a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.</li>
<li><strong>Matched wet-UFH components:</strong> 800m of heating pipe, 16 connection cores, 8-port manifold components and one Grundfos UPM3 pump/temperature-control assembly.</li>
<li><strong>Easy layout preparation:</strong> integrated panel cutting grooves help installers work around walls and changes in room shape.</li>
</ul>
<h2>What is included in the 160m² kit?</h2>
<table><thead><tr><th>Component</th><th>Included quantity / detail</th></tr></thead><tbody>
<tr><td><a href="https://thermriteshop.co.uk/products/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe">SpiderFix16 pipe-fixing panels</a></td><td>223 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 160.56m², before cuts/waste</td></tr>
<tr><td><a href="https://thermriteshop.co.uk/collections/multilayer-underfloor-heating-pipe-thermrite">16mm water underfloor heating pipe</a></td><td>800 metres in total; coil breakdown to be confirmed when supplied</td></tr>
<tr><td>Pipe reaming tool</td><td>1 deburring and chamfering tool</td></tr>
<tr><td>Compatible 16mm connector cores</td><td>16 pcs (two per manifold circuit)</td></tr>
<tr><td><a href="https://thermriteshop.co.uk/products/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges">Underfloor heating manifold components</a></td><td>8-port manifold setup</td></tr>
<tr><td><a href="https://thermriteshop.co.uk/products/automated-temperature-controller-and-grundfos-pump-assembly">Grundfos UPM3 pump pack and temperature control unit</a></td><td>1 pump and mixing/temperature-control assembly</td></tr>
</tbody></table>
<h2>SpiderFix16 technical specifications – 160m²</h2>
<table><thead><tr><th>Specification</th><th>Detail</th></tr></thead><tbody>
<tr><td>Nominal heating area</td><td>Up to 160m² (subject to project design and wastage)</td></tr>
<tr><td>Panel dimensions</td><td>1200 × 600 × 20mm; 0.72m² per panel</td></tr>
<tr><td>Pipe diameter / design spacing</td><td>16mm pipe at 200mm centres</td></tr>
<tr><td>Pipe allowance</td><td>800m total, nominally 5m per m²</td></tr>
<tr><td>Manifold size</td><td>8 ports</td></tr>
<tr><td>Panel fixing</td><td>Self-adhesive backing with interlocking connectors over an approved prepared substrate</td></tr>
<tr><td>System covering</td><td>Compatible flexible fibre-reinforced self-levelling compound (not included)</td></tr>
</tbody></table>
<h2>Where is this 160m² SpiderFix16 system best used?</h2>
<p>This kit is intended for a whole-ground-floor heating project. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.</p>
<h2>Installation and important inclusions</h2>
<p>Prepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. <strong>The 20mm panel is not the finished floor height.</strong></p>
<p><strong>Not included:</strong> levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.</p>
<p>For compatible room controls, explore <a href="https://thermriteshop.co.uk/collections/thermostats-and-controls">ThermRite thermostats and wiring controls</a>. You can also read the <a href="https://thermriteshop.co.uk/pages/underfloor-heating-board-panels-information-centre">underfloor heating boards and panels guide</a> or compare <a href="https://thermriteshop.co.uk/collections/spiderfix-panels-castellated-ufh-panels">SpiderFix and castellated pipe-fixing panels</a>. If your layout is unusually complex, request a tailored UFH design before ordering.</p>