{"title":"SpiderFix16 Complete Underfloor Heating Kits | 16mm Pipe","description":"\u003cp\u003eUpgrade your project with a SpiderFix16 low-profile UFH kit: 20mm panels, 16mm pipe, manifold and Grundfos UPM3 pump. For small-room retrofits.\u003c\/p\u003e","products":[{"product_id":"20m2-thermrite-spiderfix16-low-profile-underfloor-heating-kit","title":"20m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e20m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a small kitchen, bathroom or utility-room renovation. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eA compact project where the low-profile panel helps keep the pipe secure with a straightforward panel-based layout. This 20m² SpiderFix16 kit includes \u003cstrong\u003e28 self-adhesive panels, 100m of 16mm pipe, 4 compatible connector cores, a 2-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 20m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 100m of heating pipe, 4 connection cores, 2-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 20m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e28 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 20.16m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e100 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e4 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 20m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 20m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e100m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 20m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for a small kitchen, bathroom or utility-room renovation. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54185981706506,"sku":"SP16-20","price":510.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"30m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"30m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e30m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a kitchen refit or a modest extension. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eA straightforward single-area installation where the correct pipe layout and floor finish still need to be assessed. This 30m² SpiderFix16 kit includes \u003cstrong\u003e42 self-adhesive panels, 150m of 16mm pipe, 4 compatible connector cores, a 2-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 30m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 150m of heating pipe, 4 connection cores, 2-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 30m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e42 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 30.24m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e150 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e4 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 30m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 30m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e150m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 30m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for a kitchen refit or a modest extension. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54185984164106,"sku":"SP16-30","price":639.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"40m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"40m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e40m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a combined kitchen and dining-space refurbishment. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eA well-insulated room or open-plan zone that benefits from water UFH distributed across the floor. This 40m² SpiderFix16 kit includes \u003cstrong\u003e56 self-adhesive panels, 200m of 16mm pipe, 4 compatible connector cores, a 2-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 40m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 200m of heating pipe, 4 connection cores, 2-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 40m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e56 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 40.32m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e200 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e4 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 40m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 40m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e200m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 40m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for a combined kitchen and dining-space refurbishment. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186008936714,"sku":"SP16-40","price":761.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"50m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"50m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e50m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a medium-sized home extension. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eUseful for a ground-floor upgrade with one or more rooms served from a centrally positioned manifold. This 50m² SpiderFix16 kit includes \u003cstrong\u003e70 self-adhesive panels, 250m of 16mm pipe, 6 compatible connector cores, a 3-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 50m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 250m of heating pipe, 6 connection cores, 3-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 50m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e70 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 50.4m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e250 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e6 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 50m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 50m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e250m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e3 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 50m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for a medium-sized home extension. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186009428234,"sku":"SP16-50","price":909.53,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"60m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"60m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e60m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a larger kitchen, living room or extension. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eSuitable when the proposed pipe routes, manifold location and floor build-up have been planned together. This 60m² SpiderFix16 kit includes \u003cstrong\u003e84 self-adhesive panels, 300m of 16mm pipe, 6 compatible connector cores, a 3-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 60m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 300m of heating pipe, 6 connection cores, 3-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 60m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e84 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 60.48m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e300 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e6 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 60m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 60m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e300m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e3 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 60m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for a larger kitchen, living room or extension. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186025648394,"sku":"SP16-60","price":1031.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"70m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"70m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e70m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for an open-plan kitchen and living space. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eA practical starting point for a multi-circuit system in a well-insulated renovation. This 70m² SpiderFix16 kit includes \u003cstrong\u003e98 self-adhesive panels, 350m of 16mm pipe, 8 compatible connector cores, a 4-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 70m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 350m of heating pipe, 8 connection cores, 4-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 70m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e98 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 70.56m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e350 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e8 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 70m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 70m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e350m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e4 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 70m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for an open-plan kitchen and living space. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186046947594,"sku":"SP16-70","price":1179.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"80m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"80m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e80m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a substantial ground-floor renovation. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eAppropriate for wider floor areas with several heating circuits and a carefully considered manifold position. This 80m² SpiderFix16 kit includes \u003cstrong\u003e112 self-adhesive panels, 400m of 16mm pipe, 8 compatible connector cores, a 4-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 80m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 400m of heating pipe, 8 connection cores, 4-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 80m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e112 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 80.64m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e400 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e8 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 80m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 80m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e400m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e4 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 80m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for a substantial ground-floor renovation. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186142597386,"sku":"SP16-80","price":1300.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"90m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"90m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e90m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a large open-plan ground floor. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\u003cp\u003eA multi-circuit package for larger areas where heat loss, zones and floor finishes have been allowed for. This 90m² SpiderFix16 kit includes \u003cstrong\u003e125 self-adhesive panels, 450m of 16mm pipe, 10 compatible connector cores, a 5-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey benefits of the 90m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 450m of heating pipe, 10 connection cores, 5-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is included in the 90m² kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e125 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 90m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e450 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e10 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpiderFix16 technical specifications – 90m²\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 90m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e450m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e5 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere is this 90m² SpiderFix16 system best used?\u003c\/h2\u003e\n\u003cp\u003eThis kit is intended for a large open-plan ground floor. For a single room or smaller extension, measure the net heated area after excluding permanent fixed units. Confirm that 200mm pipe spacing will deliver the required heat output before choosing the kit size. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186157244682,"sku":"SP16-90","price":1447.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"100m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"100m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e100m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a multi-room ground-floor renovation. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\u003cp\u003eA helpful option when several rooms or heating areas share a central manifold and pump set. This 100m² SpiderFix16 kit includes \u003cstrong\u003e139 self-adhesive panels, 500m of 16mm pipe, 10 compatible connector cores, a 5-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey benefits of the 100m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 500m of heating pipe, 10 connection cores, 5-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is included in the 100m² kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e139 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 100.08m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e500 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e10 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpiderFix16 technical specifications – 100m²\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 100m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e500m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e5 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere is this 100m² SpiderFix16 system best used?\u003c\/h2\u003e\n\u003cp\u003eThis kit is intended for a multi-room ground-floor renovation. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186168451338,"sku":"SP16-100","price":1568.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"120m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"120m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e120m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a sizeable extension or multiple living areas. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\u003cp\u003eA six-port manifold arrangement that should be matched to the room-by-room heat-loss calculation. This 120m² SpiderFix16 kit includes \u003cstrong\u003e167 self-adhesive panels, 600m of 16mm pipe, 12 compatible connector cores, a 6-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey benefits of the 120m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 600m of heating pipe, 12 connection cores, 6-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is included in the 120m² kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e167 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 120.24m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e600 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e12 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpiderFix16 technical specifications – 120m²\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 120m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e600m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e6 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere is this 120m² SpiderFix16 system best used?\u003c\/h2\u003e\n\u003cp\u003eThis kit is intended for a sizeable extension or multiple living areas. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186178642186,"sku":"SP16-120","price":1843.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"140m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"140m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e140m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a large multi-room property refurbishment. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\u003cp\u003eSuited to a planned seven-circuit layout where zoning and manifold location matter. This 140m² SpiderFix16 kit includes \u003cstrong\u003e195 self-adhesive panels, 700m of 16mm pipe, 14 compatible connector cores, a 7-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey benefits of the 140m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 700m of heating pipe, 14 connection cores, 7-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is included in the 140m² kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e195 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 140.4m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e700 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e14 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpiderFix16 technical specifications – 140m²\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 140m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e700m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e7 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere is this 140m² SpiderFix16 system best used?\u003c\/h2\u003e\n\u003cp\u003eThis kit is intended for a large multi-room property refurbishment. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186179297546,"sku":"SP16-140","price":2113.63,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"160m2-thermrite-spiderfix16-low-profile-underfloor-heating-kit","title":"160m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003e\u0026lt;p\u0026gt;The \u0026lt;strong\u0026gt;160m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u0026lt;\/strong\u0026gt; is a complete water-based underfloor heating package for a whole-ground-floor heating project. It uses \u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u0026gt;SpiderFix16'\u003ehttps:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u0026gt;SpiderFix16\u003c\/a\u003e self-adhesive pipe-fixing panels\u0026lt;\/a\u0026gt; with a \u0026lt;strong\u0026gt;20mm panel profile\u0026lt;\/strong\u0026gt; to hold \u0026lt;strong\u0026gt;16mm UFH pipe\u0026lt;\/strong\u0026gt; in a designed \u0026lt;strong\u0026gt;200mm-centre layout\u0026lt;\/strong\u0026gt;. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u0026lt;\/p\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;p\u0026gt;An eight-port system for extensive installations needing coordinated circuit layout and commissioning. This 160m² SpiderFix16 kit includes \u0026lt;strong\u0026gt;223 self-adhesive panels, 800m of 16mm pipe, 16 compatible connector cores, a 8-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u0026lt;\/strong\u0026gt;.\u0026lt;\/p\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;h2\u0026gt;Key benefits of the 160m² SpiderFix16 UFH kit\u0026lt;\/h2\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;ul\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;li\u0026gt;\u0026lt;strong\u0026gt;20mm self-adhesive panels:\u0026lt;\/strong\u0026gt; low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u0026lt;\/li\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;li\u0026gt;\u0026lt;strong\u0026gt;200mm design centres:\u0026lt;\/strong\u0026gt; a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u0026lt;\/li\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;li\u0026gt;\u0026lt;strong\u0026gt;Matched wet-UFH components:\u0026lt;\/strong\u0026gt; 800m of heating pipe, 16 connection cores, 8-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u0026lt;\/li\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;li\u0026gt;\u0026lt;strong\u0026gt;Easy layout preparation:\u0026lt;\/strong\u0026gt; integrated panel cutting grooves help installers work around walls and changes in room shape.\u0026lt;\/li\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;\/ul\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;h2\u0026gt;What is included in the 160m² kit?\u0026lt;\/h2\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;table\u0026gt;\u0026lt;thead\u0026gt;\u0026lt;tr\u0026gt;\u0026lt;th\u0026gt;Component\u0026lt;\/th\u0026gt;\u0026lt;th\u0026gt;Included quantity \/ detail\u0026lt;\/th\u0026gt;\u0026lt;\/tr\u0026gt;\u0026lt;\/thead\u0026gt;\u0026lt;tbody\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;\u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u0026gt;SpiderFix16'\u003ehttps:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u0026gt;SpiderFix16\u003c\/a\u003e pipe-fixing panels\u0026lt;\/a\u0026gt;\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;223 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 160.56m², before cuts\/waste\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;\u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u0026gt;16mm'\u003ehttps:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u0026gt;16mm\u003c\/a\u003e water underfloor heating pipe\u0026lt;\/a\u0026gt;\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;800 metres in total; coil breakdown to be confirmed when supplied\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Pipe reaming tool\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;1 deburring and chamfering tool\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Compatible 16mm connector cores\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;16 pcs (two per manifold circuit)\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;\u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u0026gt;Underfloor'\u003ehttps:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u0026gt;Underfloor\u003c\/a\u003e heating manifold components\u0026lt;\/a\u0026gt;\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;8-port manifold setup\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;\u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u0026gt;Grundfos'\u003ehttps:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u0026gt;Grundfos\u003c\/a\u003e UPM3 pump pack and temperature control unit\u0026lt;\/a\u0026gt;\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;1 pump and mixing\/temperature-control assembly\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;\/tbody\u0026gt;\u0026lt;\/table\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;h2\u0026gt;SpiderFix16 technical specifications – 160m²\u0026lt;\/h2\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;table\u0026gt;\u0026lt;thead\u0026gt;\u0026lt;tr\u0026gt;\u0026lt;th\u0026gt;Specification\u0026lt;\/th\u0026gt;\u0026lt;th\u0026gt;Detail\u0026lt;\/th\u0026gt;\u0026lt;\/tr\u0026gt;\u0026lt;\/thead\u0026gt;\u0026lt;tbody\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Nominal heating area\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;Up to 160m² (subject to project design and wastage)\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Panel dimensions\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;1200 × 600 × 20mm; 0.72m² per panel\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Pipe diameter \/ design spacing\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;16mm pipe at 200mm centres\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Pipe allowance\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;800m total, nominally 5m per m²\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Manifold size\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;8 ports\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;Panel fixing\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;Self-adhesive backing with interlocking connectors over an approved prepared substrate\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;tr\u0026gt;\u0026lt;td\u0026gt;System covering\u0026lt;\/td\u0026gt;\u0026lt;td\u0026gt;Compatible flexible fibre-reinforced self-levelling compound (not included)\u0026lt;\/td\u0026gt;\u0026lt;\/tr\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;\/tbody\u0026gt;\u0026lt;\/table\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;h2\u0026gt;Where is this 160m² SpiderFix16 system best used?\u0026lt;\/h2\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;p\u0026gt;This kit is intended for a whole-ground-floor heating project. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u0026lt;\/p\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;h2\u0026gt;Installation and important inclusions\u0026lt;\/h2\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;p\u0026gt;Prepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u0026lt;strong\u0026gt;The 20mm panel is not the finished floor height.\u0026lt;\/strong\u0026gt;\u0026lt;\/p\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;p\u0026gt;\u0026lt;strong\u0026gt;Not included:\u0026lt;\/strong\u0026gt; levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u0026lt;\/p\u0026gt;\u003c\/p\u003e\u003cp\u003e\u0026lt;p\u0026gt;For compatible room controls, explore \u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u0026gt;ThermRite'\u003ehttps:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u0026gt;ThermRite\u003c\/a\u003e thermostats and wiring controls\u0026lt;\/a\u0026gt;. You can also read the \u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u0026gt;underfloor'\u003ehttps:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u0026gt;underfloor\u003c\/a\u003e heating boards and panels guide\u0026lt;\/a\u0026gt; or compare \u0026lt;a href=\"\u003ca target=\"_blank\" rel=\"noopener noreferrer nofollow\" href='https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u0026gt;SpiderFix'\u003ehttps:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u0026gt;SpiderFix\u003c\/a\u003e and castellated pipe-fixing panels\u0026lt;\/a\u0026gt;. If your layout is unusually complex, request a tailored UFH design before ordering.\u0026lt;\/p\u0026gt;\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186182967562,"sku":"SP16-160","price":2383.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"180m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"180m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e180m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a large renovation with multiple heated rooms. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\u003cp\u003eA nine-port configuration where hydraulic balance and room controls should be designed in advance. This 180m² SpiderFix16 kit includes \u003cstrong\u003e250 self-adhesive panels, 900m of 16mm pipe, 18 compatible connector cores, a 9-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey benefits of the 180m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 900m of heating pipe, 18 connection cores, 9-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is included in the 180m² kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e250 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 180m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e900 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e18 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e9-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpiderFix16 technical specifications – 180m²\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 180m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e900m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e9 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere is this 180m² SpiderFix16 system best used?\u003c\/h2\u003e\n\u003cp\u003eThis kit is intended for a large renovation with multiple heated rooms. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186199122186,"sku":"SP16-180","price":2646.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"200m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"200m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e200m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a large domestic or light-commercial floor heating project. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\n\u003cp\u003eA ten-port configuration requiring a detailed design for circuit lengths and heating loads. This 200m² SpiderFix16 kit includes \u003cstrong\u003e278 self-adhesive panels, 1,000m of 16mm pipe, 20 compatible connector cores, a 10-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey benefits of the 200m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 1,000m of heating pipe, 20 connection cores, 10-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat is included in the 200m² kit?\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e278 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 200.16m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e20 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpiderFix16 technical specifications – 200m²\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 200m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e1,000m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e10 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhere is this 200m² SpiderFix16 system best used?\u003c\/h2\u003e\n\n\u003cp\u003eThis kit is intended for a large domestic or light-commercial floor heating project. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186199449866,"sku":"SP16-200","price":2915.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"220m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"220m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e220m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for an extensive multi-zone heating installation. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\u003cp\u003eAn eleven-port configuration for substantial floor areas, best specified from a detailed drawing. This 220m² SpiderFix16 kit includes \u003cstrong\u003e306 self-adhesive panels, 1,100m of 16mm pipe, 22 compatible connector cores, a 11-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey benefits of the 220m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 1,100m of heating pipe, 22 connection cores, 11-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is included in the 220m² kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e306 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 220.32m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,100 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e22 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e11-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpiderFix16 technical specifications – 220m²\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 220m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e1,100m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e11 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere is this 220m² SpiderFix16 system best used?\u003c\/h2\u003e\n\u003cp\u003eThis kit is intended for an extensive multi-zone heating installation. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186200203530,"sku":"SP16-220","price":3185.48,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"},{"product_id":"240m-spiderfix16-ufh-kit-200mm-centres-thermrite","title":"240m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit","description":"\u003cp\u003eThe \u003cstrong\u003e240m² ThermRite SpiderFix16 Low-Profile Underfloor Heating Kit – 200mm Centres\u003c\/strong\u003e is a complete water-based underfloor heating package for a large multi-room or light-commercial UFH project. It uses \u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 self-adhesive pipe-fixing panels\u003c\/a\u003e with a \u003cstrong\u003e20mm panel profile\u003c\/strong\u003e to hold \u003cstrong\u003e16mm UFH pipe\u003c\/strong\u003e in a designed \u003cstrong\u003e200mm-centre layout\u003c\/strong\u003e. The panels are intended to be covered by a suitable flexible, fibre-reinforced self-levelling compound, providing a secure, low-profile fixing system for water underfloor heating.\u003c\/p\u003e\n\u003cp\u003eA twelve-port configuration that warrants a room-by-room heat-loss and circuit-length design. This 240m² SpiderFix16 kit includes \u003cstrong\u003e334 self-adhesive panels, 1,200m of 16mm pipe, 24 compatible connector cores, a 12-port manifold, a pipe reaming tool, and a Grundfos UPM3 pump pack with temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey benefits of the 240m² SpiderFix16 UFH kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20mm self-adhesive panels:\u003c\/strong\u003e low-profile recycled-plastic panels with interlocking joints and secure retention for 16mm pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200mm design centres:\u003c\/strong\u003e a practical pipe layout for suitable, well-insulated rooms with moderate heating requirements; verify the final layout against heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched wet-UFH components:\u003c\/strong\u003e 1,200m of heating pipe, 24 connection cores, 12-port manifold components and one Grundfos UPM3 pump\/temperature-control assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy layout preparation:\u003c\/strong\u003e integrated panel cutting grooves help installers work around walls and changes in room shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is included in the 240m² kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eIncluded quantity \/ detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/spiderfix16-ufh-pipe-fixing-panel-for-16mm-pipe\"\u003eSpiderFix16 pipe-fixing panels\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e334 panels × 0.72m² each (1200 × 600 × 20mm); nominal panel coverage 240.48m², before cuts\/waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/multilayer-underfloor-heating-pipe-thermrite\"\u003e16mm water underfloor heating pipe\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,200 metres in total; coil breakdown to be confirmed when supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe reaming tool\u003c\/td\u003e\n\u003ctd\u003e1 deburring and chamfering tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 16mm connector cores\u003c\/td\u003e\n\u003ctd\u003e24 pcs (two per manifold circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/thermrite-stainless-steel-ufh-manifold-flow-meters-temp-gauges\"\u003eUnderfloor heating manifold components\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12-port manifold setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/thermriteshop.co.uk\/products\/automated-temperature-controller-and-grundfos-pump-assembly\"\u003eGrundfos UPM3 pump pack and temperature control unit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pump and mixing\/temperature-control assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpiderFix16 technical specifications – 240m²\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating area\u003c\/td\u003e\n\u003ctd\u003eUp to 240m² (subject to project design and wastage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel dimensions\u003c\/td\u003e\n\u003ctd\u003e1200 × 600 × 20mm; 0.72m² per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter \/ design spacing\u003c\/td\u003e\n\u003ctd\u003e16mm pipe at 200mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe allowance\u003c\/td\u003e\n\u003ctd\u003e1,200m total, nominally 5m per m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold size\u003c\/td\u003e\n\u003ctd\u003e12 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel fixing\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with interlocking connectors over an approved prepared substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem covering\u003c\/td\u003e\n\u003ctd\u003eCompatible flexible fibre-reinforced self-levelling compound (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere is this 240m² SpiderFix16 system best used?\u003c\/h2\u003e\n\u003cp\u003eThis kit is intended for a large multi-room or light-commercial UFH project. For a multi-room layout, agree the number of independent heating circuits and any room zoning before ordering. The 200mm spacing is a starting point for well-insulated areas, not a substitute for a room-by-room heat-loss calculation. With pipe on 200mm centres, heat output depends on insulation, floor finishes, design flow temperature and the specific building heat loss. Rooms requiring higher output or lower flow temperatures may need closer pipe spacing and different quantities.\u003c\/p\u003e\n\u003ch2\u003eInstallation and important inclusions\u003c\/h2\u003e\n\u003cp\u003ePrepare a clean, sound and suitable subfloor; use the required substrate preparation and primer. Connect the SpiderFix16 panels, install the heating pipe in the specified routes and pressure-test all circuits. Cover the system with a compatible flexible fibre-reinforced self-levelling compound to the compound manufacturer’s required depth, then follow its drying and commissioning instructions before laying the finished floor. \u003cstrong\u003eThe 20mm panel is not the finished floor height.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e levelling compound, primer, thermal insulation, necessary perimeter-isolation materials, floor finishes, the heating appliance, wiring controls and room thermostats, unless separately specified. Perimeter isolation can still be required by the chosen floor build-up and levelling compound.\u003c\/p\u003e\n\u003cp\u003eFor compatible room controls, explore \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/thermostats-and-controls\"\u003eThermRite thermostats and wiring controls\u003c\/a\u003e. You can also read the \u003ca href=\"https:\/\/thermriteshop.co.uk\/pages\/underfloor-heating-board-panels-information-centre\"\u003eunderfloor heating boards and panels guide\u003c\/a\u003e or compare \u003ca href=\"https:\/\/thermriteshop.co.uk\/collections\/spiderfix-panels-castellated-ufh-panels\"\u003eSpiderFix and castellated pipe-fixing panels\u003c\/a\u003e. If your layout is unusually complex, request a tailored UFH design before ordering.\u003c\/p\u003e","brand":"ThermRite Ltd","offers":[{"title":"Default Title","offer_id":54186203611402,"sku":"SP16-240","price":3455.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/files\/temp_60Vu5WD.png?v=1795171584"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/1782\/5546\/collections\/temp_60Vu5WD_6bc18c92-0dab-4c40-a4bc-ca7b207259bc.jpg?v=1795190459","url":"https:\/\/thermriteshop.co.uk\/collections\/spiderfix16-underfloor-heating-kits-thermrite.oembed","provider":"ThermRite Shop","version":"1.0","type":"link"}